Data Center Liquid Cooling Hoses & Quick Disconnect Couplings

Reliable liquid cooling hoses and dry-break quick disconnect couplings for AI servers, GPU clusters, CDUs, server racks, and high-density data center cooling systems.

Data Center Liquid Cooling Solutions
Home Hot Liquid Cooling Hose Couplings

Liquid Cooling Hose & Coupling Solutions

We provide liquid cooling hoses and quick disconnect couplings engineered for coolant distribution across modern data center liquid cooling loops. Our solutions connect CDUs, manifolds, server racks, and cold plate systems while supporting stable coolant flow, electrical insulation, system cleanliness, and easier maintenance.


Our range includes non-conductive EPDM cooling hoses, low-extractable coolant hoses, and OCP-compliant dry-break quick disconnect couplings. Depending on the selected hose model, solutions are available for high-purity water, deionized water, glycol mixtures, and other commonly used cooling media.


For AI computing, HPC, and other high-density applications, we help customers select compatible hose and coupling configurations based on coolant type, pressure, insulation requirements, cleanliness, routing, and connection method.

Liquid Cooling Products

Choose from data center cooling hoses and quick disconnect couplings for CDU distribution, rack-level coolant delivery, cold plate connections, and high-density computing infrastructure.

Why Choose Our Liquid Cooling Hoses & Couplings?

Our goal is to provide reliable hose and coupling solutions for high-density data center liquid cooling systems.

Non-Drip Quick Disconnect Design

Dry-Break Quick Disconnect Connections

Our DCLC Series quick disconnect couplings use a dry-break flat-face valve design to minimize coolant loss during connection and disconnection. The high-flow, low-pressure-drop structure supports efficient coolant circulation, while 100% helium leak testing provides additional verification for demanding liquid cooling applications.

High-Insulation EPDM Hose Options

Our EPDM liquid cooling hoses include non-conductive and high-insulation options for coolant routing around sensitive electrical equipment. Selected models are available with UL94 V0 flame-retardant construction, ozone and abrasion resistance, and compatibility with deionized water and glycol-based coolants.

High-Insulation EPDM Cooling Hose

Liquid Cooling Product Options & Key Specifications

Our liquid cooling portfolio combines quick disconnect couplings, high-insulation EPDM hoses, and low-extractable cooling hoses for different locations within data center coolant distribution systems.

DCLC Quick Disconnect Coupling

DCLC Quick Disconnect Coupling

OCP-compliant UQD/UQDB dry-break coupling designed for liquid cooling connections in AI servers, GPU clusters, CDUs, HPC systems, and rack-level cooling infrastructure.


Model: DCLC

Material: SS316 + EPDM

Connection: Dry-break quick disconnect

Testing: 100% helium leak testing

Typical Use: CDU, manifold, rack and server liquid cooling connections

Non-Conductive EPDM Cooling Hose

Non-Conductive EPDM Cooling Hose

High-insulation EPDM cooling hose designed for coolant transfer between CDUs, manifolds, server racks, and other liquid cooling equipment.


Model: SKW

Insulation: Up to 6000V

Pressure: 20 bar / 300 PSI

Material: EPDM

Typical Use: CDU distribution and server rack coolant routing

DCC800 Data Center Cooling Hose

DCC800 Data Center Cooling Hose

Low-extractable EPDM hose developed for clean liquid cooling circuits where flame resistance and coolant cleanliness are important considerations.


Model: DCC800

Cleanliness: 150 μm

Fire Rating: UL94 V0

Material: EPDM

Typical Use: Data center and precision coolant circulation systems

Applications in Data Center Liquid Cooling

ChatGPT Image Jul 2, 2026, 04_29_33 PM

AI Servers & GPU Clusters

Our liquid cooling hoses and quick disconnect couplings support coolant delivery to cold plates and other rack-level cooling components used in AI servers and GPU clusters. They help maintain dependable coolant circulation as computing density and thermal loads increase.

ChatGPT Image Jul 2, 2026, 04_28_45 PM

CDU, Manifold & Server Rack Cooling

Use our cooling hoses for secondary-loop coolant distribution between CDUs, manifolds, server racks, and connected cooling equipment. Hose and coupling configurations can be selected according to pressure, flow, routing, insulation, and maintenance requirements.

ChatGPT Image Jul 2, 2026, 05_32_19 PM

HPC & High-Density Computing

For HPC systems, research computing centers, and other high-density environments, we provide hose and coupling options designed around coolant purity, electrical insulation, low leakage, and reliable fluid transfer.

2028659933204578317-bg

Custom Liquid Cooling Hose & Coupling Solutions

Liquid cooling systems vary by rack architecture, CDU configuration, coolant, pressure, routing space, and connection design. We support project-specific hose and coupling selection to help customers build suitable fluid distribution assemblies.

Custom Hose Specifications

We support customized hose dimensions, pressure grades, colors, surface requirements, and routing configurations for different liquid cooling layouts.

Coupling Configuration Support

Quick disconnect coupling configurations can be selected according to connection method, installation location, flow requirements, maintenance needs, and system architecture.

Material & Performance Options

Available options include high-insulation EPDM, UL94 V0 flame-retardant construction, halogen-free materials, low-extractable hose designs, and project-specific material configurations.

Samples & Technical Documentation

For project evaluation, we can provide available samples, product specifications, test reports, and relevant certification documents to support technical review before ordering.

beijingtu

Planning a Data Center Liquid Cooling Project?

Send us your coolant type, hose size, working pressure, temperature range, insulation requirements, connection type, and application details. Our team can help you evaluate suitable liquid cooling hoses and quick disconnect couplings for CDUs, manifolds, server racks, AI servers, and other cooling equipment.

Liquid Cooling Technical Resources

  • Name
  • Downloads
  • Thumbnail
  • Download
  • Copy Link
  • Fire breathing tube sample booklet
  • 73
  • Download
  • Water and gas multi-purpose pipe sample booklet
  • 91
  • Download
  • Hot water steam pipe sample booklet
  • 90
  • Download
  • Wear-resistant material tube sample booklet
  • 94
  • Download
  • Chemical transfer pipe sample booklet
  • 85
  • Download

Frequently Asked Questions

Q: What are Scomera liquid cooling hose and couplings used for?
A: They are used in data center liquid cooling systems, including AI servers, GPU clusters, CDUs, server racks, HPC systems, edge computing systems, and high-density cooling loops.
Q: Why choose dry-break quick disconnect couplings for liquid cooling?
A: Dry-break flat-face couplings help prevent coolant spillage during connection and disconnection. Scomera DCLC couplings also undergo 100% helium leak testing for critical data center operation.
Q: What cooling media can Scomera EPDM hoses handle?
A: Scomera EPDM cooling hoses are suitable for high-purity water, deionized water, glycol mixtures, propylene glycol solutions, refrigerants, and various coolants depending on the hose model.
Q: Are the hoses suitable for data center electrical safety requirements?
A: Yes. Several Scomera hose options are non-conductive, with high-insulation EPDM construction, UL94 V0 flame-retardant covers, and resistance values designed for data center cooling safety requirements.
Q: Can Scomera provide customized hose specifications?
A: Yes. Scomera supports customized sizes, colors, surface finishes, pressure grades, and project-specific production plans, along with specification documents, testing support, and quality verification.

Quality & Compliance Support

We support liquid cooling projects with available product specifications, test documentation, and certification information. Our product range includes OCP-compliant quick disconnect coupling options and UL94 V0 liquid cooling hose options for applications requiring documented performance and material evaluation.

zs002
zs001
zs07
zs091
zs02
zs04
zs03
zs05
zs06
zs08
zs09
zs01

Related Blogs

23

Liquid Cooling Manufacturing & Testing

Explore our production, quality control, testing, and customization capabilities for cooling hoses and fluid connection products. We support project-specific requirements for data center cooling, industrial fluid transfer, and customized hose and coupling assemblies.

Talk to Our Liquid Cooling Team

Need help selecting a data center liquid cooling hose or quick disconnect coupling?


Tell us about your CDU, rack, server, coolant, pressure, temperature, hose size, or connection requirements. We can provide product information, available technical documents, customization support, and suitable product recommendations for your cooling system.

Mob: +86-400-100-1142 / +86-18501903436

LEAVE US YOUR INFO
Scomera(Beijing)Technology Company Limited is a specialized company operating in a challenging environment. Adhering to the core value of providing excellent solutions to our customers, we offer valuable products and services.

CONTACT US

 No. 496, Xiangtun, Xingshou Town, Changping District, Beijing
 +86-18501903436
 +8618601285155
Copyright ©  2026 Scomera(Beijing)Technology Company Limited All rights reserved. | Sitemap